| Sign In | Join Free | My benadorassociates.com | 
 | 
Brand Name : Honeywell
Model Number : CC-PAIX01
Place of Origin : USA
MOQ : 1
Price : negotiable
Payment Terms : TT West Union
Supply Ability : 100
Delivery Time : 2-3 work days
Packaging Details : New in original box
Brand : Honeywell
Model : 51405038-275
Series : TCD3000
ASSY : K
Type : Profibus Dp Gateway Module
Honeywell CC-PAIX01 51405038-275 Analog Input Module NEW AND ORIGINAL PACKAGE IN STOCK 
  
  
 QUICK DETAILS
 
 DESCRIPTION
OTHER SUPERIOR PRODUCTS
| Yasakawa Motor, Driver SG- | Mitsubishi Motor HC-,HA- | 
| Westinghouse Modules 1C-,5X- | Emerson VE-,KJ- | 
| Honeywell TC-,TK- | GE Modules IC - | 
| Fanuc motor A0- | Yokogawa transmitter EJA- | 
                                      
Planning Considerations
 Implementing an ELMM solution begins by planning for the following:
 • Network topology: Understand how ELMM connects to LCN.
 • EUCN Planning: ELMM connects to EUCN (UCN over FTE). See UCN Planning guide for more details.
 • Site Selection: Dimensions of existing LM cabinets are marginally different from Series C cabinets that
 house ELMMs. Analyze this and work out the location of the new cabinet. Wiring and grounding for the
 new cabinet and its hardware components must be planned. ELMM comes factory-fitted in a Series C
 cabinet. If your plan is to use an existing UCN cabinet to house the ELMMs, estimate for activities for
 mounting ELMM hardware and its components and wiring them.
 • ELMM and C300 controllers: The number of modules needed based on your requirements, or based
 on the number of LM processors being replaced.
 • ELMM redundancy: ELMM supports redundancy. Plan the number of controllers and ELMMs required if
 you want redundancy, or if the LMs being replaced are redundant.
 • IOs: C300 communicates with an entirely different set of IOs (Series C IOs) compared to LM. Map the
 existing IOs with their Series C IO or PMIO equivalents in the planning stage itself. If equivalent LM IOs
 are unavailable, an engineering solution may have to be found. If you have existing remote IOs, connect
 them via Series C Fiber Optics Extenders.
Other Modules
CC-PCF901 PWA MODULE, CONTROL FIREWALL 9 G3 CC C300 
 CC-PCNT01 PWA MODULE, C300 CONTROL PROCESSOR C300
 CC-TCF901 PWA, CNTRL FIREWALL IOTA 8 PORT 1 UPLINK C300
 CC-TCNT01 PWA, C300 CONTROL PROCESSOR IOTA CC C300
CC-SCMB02 MODULE ASSY, MEMORY BACKUP C300 C300
 51199942-300 BATTERY PACK C300
 CC-PWRR01 POWER ASSY, RED 20A W/O BBU 
 51199929-100 PWA SUPPLY MODULE
 CC-PAIX01 PWA MODULE, HLAI G3 CE CC AI 
 CC-PAIH01 PWA MODULE, HART HLAI G3 CE CC 
 CC-TAIX11 PWA, AI IOTA RED 16 12IN CE CC 
 CC-TAIX01 PWA, AI IOTA 16 6IN CE CC 
 CC-PAOX01 PWA MODULE, AO G3CE CC AO
 CC-TAOX11 PWA, AO IOTA RED 16 12IN CE CC 
 CC-TAOX01 PWA, AO IOTA 16 6IN CE CC 
 CC-PDIL01 PWA MODULE, DI 24V IO G3 CE CC DI
 CC-PDIS01 MODULE, DISOE 24V ASSY G3 24V
 CC-TDIL01 PWA, DI 24VAC IOTA 
 CC-TDIL11 PWA, DI 24V IOTA RED 32 24V
 CC-PDOB01 PWA MODULE, DO 24V IO G3 CE CC DO
 CC-TDOB01 PWA, DO 24V BUSS IOTA 32 24V
 CC-TDOB11 PWA, DO 24V BUSS IOTA RED 32 24V
 CC-PAIM01 PWA MOD, LLAMUX G3 CE CC 
 CC-TAIM01 PWA, PMIO LLMUX IOTA 64PT CE CC
Fluorinated Gases: Hydrofluorocarbons (HFCs), perfluorocarbons (PFCs) and sulfur hexafluoride (SF6) are synthetic, powerful greenhouse gases that are emitted from a variety of industrial processes. Fluorinated gases are sometimes used as substitutes for ozone-depleting substances (i.e., CFCs, HCFCs and halons). These gases are typically emitted in smaller quantities, but because they are potent greenhouse gases, they are sometimes referred to as High Global Warming Potential gases (High GWP gases). HFCs are 140 to 11,700 times more potent than CO2 and have atmospheric lifespans of 1–260 years. Most commercially used HFCs remain in the atmosphere less than 15 years. PFCs are 6,500 to 9,200 times more potent than CO2 and have an atmospheric lifespan of several thousand years. Sulfur hexafluoride is 23,900 times a more potent greenhouse gas than CO2 and is extremely long lived with very few sinks (EPA, 2009c).
Projected change in annual mean surface air temperature from the late 20th century (1971-2000 average) to the middle 21st century (2051-2060 average). The change is in response to increasing greenhouse gases and aerosols based on a middle of the road estimate of future emissions. Warming is larger over continents than oceans, and is largest at high latitudes of the Northern Hemisphere. These results are from the GFDL CM2.1 model but are consistent with a broad consensus of modeling results.

|   | 
| Honeywell CC-PAIX01 51405038-275 Analog Input Module NEW AND ORIGINAL PACKAGE IN STOCK Images | 
 Power Supply Redundancy Module Emerson KJ3201X1-BA1 Delta-V Dry Contact Card
                                                                                    
                        
                        
                        
                                                            Power Supply Redundancy Module Emerson KJ3201X1-BA1 Delta-V Dry Contact Card
                                                    
                        
                     3.3VDC 500mA Max Control Interface Module DELTAV KJ2004X1-BA1 12P2890X012
                                                                                    
                        
                        
                        
                                                            3.3VDC 500mA Max Control Interface Module DELTAV KJ2004X1-BA1 12P2890X012
                                                    
                        
                     Electronic Interface Module / PLC Input Module KJ2002X1-CA1 VE3004 12P1509X092
                                                                                    
                        
                        
                        
                                                            Electronic Interface Module / PLC Input Module KJ2002X1-CA1 VE3004 12P1509X092
                                                    
                        
                     Durable Emerson Redundant Power Supply Module VE3006 KJ2003X1-BB1 1.4AMP 5VDC
                                                                                    
                        
                        
                        
                                                            Durable Emerson Redundant Power Supply Module VE3006 KJ2003X1-BB1 1.4AMP 5VDC
                                                    
                        
                     Dry Contact Card Redundant Power Supply Module KJ3001X1-BB1 DI , 8-Channel 24
                                                                                    
                        
                        
                        
                                                            Dry Contact Card Redundant Power Supply Module KJ3001X1-BB1 DI , 8-Channel 24
                                                    
                        
                     Emerson DeltaV VE3006 KJ2003X1-BB1 MD Plus Controller Redundant Power Supply
                                                                                    
                        
                        
                        
                                                            Emerson DeltaV VE3006 KJ2003X1-BB1 MD Plus Controller Redundant Power Supply
                                                    
                        
                     KJ3002X1-BC1 Power Interface Module 2 24vdc Discr Controller MD Plus
                                                                                    
                        
                        
                        
                                                            KJ3002X1-BC1 Power Interface Module 2 24vdc Discr Controller MD Plus
                                                    
                        
                     KJ3201X1-BA1 DI 8 Channel Redundant Power Supply Module 24 VDC Dry C MD Plus
                                                                                    
                        
                        
                        
                                                            KJ3201X1-BA1 DI 8 Channel Redundant Power Supply Module 24 VDC Dry C MD Plus
                                                    
                        
                     HART Series 2 Red Redundant Power Supply Module KJ3221X1-BA1 AO 4-20 MA
                                                                                    
                        
                        
                        
                                                            HART Series 2 Red Redundant Power Supply Module KJ3221X1-BA1 AO 4-20 MA
                                                    
                        
                     KJ4001X1-BE1 8 Input Interface Module / Analog I O Module With Shield Bar
                                                                                    
                        
                        
                        
                                                            KJ4001X1-BE1 8 Input Interface Module / Analog I O Module With Shield Bar